Showing results: 121 - 135 of 149 items found.
-
PEWM-3C-1 -
EMSYST Ltd
The single-phase energy standard PEWM-3C-1-1 is used for a quick check on site of all types single-phase electricity meters – for active, reactive or apparent energy, electromechanical and electronic. The voltage and the current are measured at the same time. The current can be measured directly within 10A or 100A range or with current clamp to 100A. The current clamp is electronically compensated.
-
Applied Meters, a.s.
The Reference Standard RS is precision standard meter in single- and three-phase version for electrical power and energy measurement. It is designed to meet all requirements put on a reference standard in a single- and three-phase electricity meter testing and calibration systems. The Reference Standard can be set to any true or artificial mode of operation in three phase system and is capable to evaluate individual quantities in any phase
-
Signals & Systems India Private Limited
SANDS make of AMR Modem SAM-1101 is a smart electricity meter reading device that can be connected to any make of electronic energy meter by means of optical/ RS232 port, which is compliant to DLMS – IEC 62056-21 standard. The electricity meters measuring energy consumption can be located in either consumer premises or in distribution transformers. The modem draws its power from the meter terminal block and connects to the communication port of the meter. Thus this add-on energy meter reading system is non-intrusive and can be retrofitted easily to any meter. The Electricity Meter Reading device uses GSM/GPRS communication technology and has built-in intelligence to talk to the DLMS meter. AMR system is compatible with 4G network to push the power consumption-billing data, load survey data, and event data to a cloud-based server, with fallback options to 3G & 2G.
-
GOLD MINER IV -
EMSYST Ltd
Gold Miner is the first device of its type to test the electricity meter using exact, simultaneous measurements made on all primary and all secondary phases of the circuit. Perform in-service meter testing with a combined 3-phase load, or a single-phase load. Gold Miner not only displays the Meter’s accuracy, but also the overall, true accuracy resulting from the CTs + Meter combination for your entire measurement circuit.
-
ELMA -
Applied Precision Ltd.
The Electricity Meter Test Equipment ELMA due to modular concept enables to tailor specifications to specific laboratory demand. The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories.
-
PEWM-3C -
EMSYST Ltd
The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).
-
Applied Meters, a.s.
Single-phase static electricity meters AMS B1x-SAx are determined for direct and indirect measurement of active energy displaying value on mechanical register with stepping motor. In the case of CT (current transformer) operated meters (x/5A) it is necessary value of register to multiply by the current transformer ratio.
-
EE-120A-3S -
EMSYST Ltd
The EE-120A-3S unit consists of a three-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types of electricity meters using the voltages of the network. The meter error can be measured for active, reactive or apparent energy in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Maximum Demand Test, Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the three-phase network – with direct measurement or with optional current clamps.
-
KoCoS Messtechnik AG
Dramatic advances in the field of measurement technology and the use of state-of-the-art micro-electronics have led to the development of a new generation of electricity meters which are far more accurate than their predecessors of just a few years ago. As well as measuring the exact amount of energy used, a high level of integration enables electronic meters to perform a number of additional functions. As a result, these meters are also more sensitive to network irregularities. This means that regular testing is the only way to ensure that a meter functions correctly, both during final factory tests and during the entire life span of a meter.
-
EE-120A-1S -
EMSYST Ltd
The EE-120A-1S unit consists of a single-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types single-phase electricity meters using the voltage of the site. The meter error can be measured for active, reactive or apparent energy, in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the site – with direct measurement or with optional current clamps.
-
TE30 -
Calmet Smart Calibration Devices
Electricity meters tester class 0.05 and 0.1. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.
-
METES -
KoCoS Messtechnik AG
Meter test systems with high accuracies of up to 0.02% and a wide measuring range for precise measurements in single- and three-phase applications. The meter test systems of the METES series are used to test the accuracy of Ferraris meters and electronic electricity meters under any operating conditions. The impact of system perturbations such as harmonics or flicker on the meter can be taken into consideration during tests.
-
Test Station -
EMSYST Ltd
The meter test station allows simultaneous testing of 3, 5, 10 or 20 induction or static electricity meters. The test station could be constructed for single-phase electricity meters or for three-phase meters.
-
PG 01-2000 -
Schlöder GmbH
The test generator PG 01-2000 is suitable for insulation test and testing of the impulse withstand voltage of electrical and electronic electricity meters. The generator produce a standard pulse voltage waveform with 0,1 / 2000 μs.
-
TB41 -
Calmet Smart Calibration Devices
The Calmet TB41 Four Position Meter Test Bench is used for calibration and simultaneously testing up to four single and three phase electromechanical and electronic acitve and reactive electricity meters with accuracy referenced to an internal reference meter (class 0.02% or 0.04%).